|
|
Registros recuperados : 90 | |
Registros recuperados : 90 | |
|
|
Registro Completo
Biblioteca(s): |
Embrapa Unidades Centrais. |
Data corrente: |
12/09/2001 |
Data da última atualização: |
20/09/2004 |
Autoria: |
OLIVEIRA, N. M. de; KENNEDY, J. P. |
Título: |
Implications of Medullation and Fibre Diameter Distribution on Wool Diameter Measured by Airflow. |
Ano de publicação: |
1992 |
Fonte/Imprenta: |
Pesquisa Agropecuaria Brasileira, Brasilia, v.27, n.12, p.1643-1657, dez.1992 |
Idioma: |
Inglês |
Conteúdo: |
The specific gravity (related to medullation as assessed by three techniques) and fibre diameter variability of 242 wool samples (encompassing the range of diameters between 22.0 and 38.0 m.m) were considered to evaluate the accuracy of diameter estimates as obtained from the Airflow apparatus. Data are presented showing the improvement obtained on diameter estimates of highly medullated wools, within a precision comparable to others reported for non-medullated fibres. Results on the techniques employed lo assess medullation (Projection Microscope, Medullameter and InfraAlyser) have also been discussed. |
Palavras-Chave: |
specific gravity coefficient of variation. |
Thesaurus NAL: |
sheep. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/AI-SEDE/20758/1/pab10_dez_92.pdf
|
Marc: |
LEADER 01124naa a2200157 a 4500 001 1105707 005 2004-09-20 008 1992 bl uuuu u00u1 u #d 100 1 $aOLIVEIRA, N. M. de 245 $aImplications of Medullation and Fibre Diameter Distribution on Wool Diameter Measured by Airflow. 260 $c1992 520 $aThe specific gravity (related to medullation as assessed by three techniques) and fibre diameter variability of 242 wool samples (encompassing the range of diameters between 22.0 and 38.0 m.m) were considered to evaluate the accuracy of diameter estimates as obtained from the Airflow apparatus. Data are presented showing the improvement obtained on diameter estimates of highly medullated wools, within a precision comparable to others reported for non-medullated fibres. Results on the techniques employed lo assess medullation (Projection Microscope, Medullameter and InfraAlyser) have also been discussed. 650 $asheep 653 $aspecific gravity coefficient of variation 700 1 $aKENNEDY, J. P. 773 $tPesquisa Agropecuaria Brasileira, Brasilia$gv.27, n.12, p.1643-1657, dez.1992
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Unidades Centrais (AI-SEDE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|